Thomas Vincent 22d19cfcc6 issue#7355: add ENTITY-SENSOR, JUNIPER and F5-BIGIP script data queries (#7839)
* issue#7355: add a vendor-neutral ENTITY-SENSOR-MIB script data query

ENTITY-SENSOR-MIB (RFC 3433) exposes physical sensors (temperature, fan, PSU,
voltage, current) on most modern gear, so one data query covers F5, Juniper,
Arista, Cisco NX-OS and others. ss_entity_sensor collects the sensor table and
scales each reading through entPhySensorScale and entPhySensorPrecision; the
SNMP I/O sits behind an injectable walker so every logic branch is unit tested.

A dedicated coverage job enforces 100% line coverage on the collector.

Signed-off-by: Thomas Vincent <thomasvincent@gmail.com>

* issue#7355: add a JUNIPER-MIB jnxOperatingTable script data query

Junos routers and switches expose per-subject health (Routing Engine, FPC, PSU,
fan) through JUNIPER-MIB jnxOperatingTable, which is the signature Juniper data
beyond the IF-MIB and HOST-RESOURCES standards. ss_juniper_operating collects
CPU, temperature, buffer and state; the multi-index table is keyed on the full
OID suffix. SNMP I/O sits behind an injectable walker so every branch is unit
tested, and a dedicated job enforces 100% line coverage.

Signed-off-by: Thomas Vincent <thomasvincent@gmail.com>

* issue#7355: add an F5-BIGIP-SYSTEM-MIB per-CPU utilization script data query

BIG-IP reports per-CPU utilization as sliding 5s/1m/5m averages in
sysMultiHostCpuTable, the signature F5 metric beyond the IF-MIB and
HOST-RESOURCES standards. ss_f5_cpu collects that multi-indexed table, keyed on
the full OID suffix. Every OID was resolved from the published
F5-BIGIP-SYSTEM-MIB with snmptranslate. SNMP I/O sits behind an injectable
walker so every branch is unit tested, and a dedicated job enforces 100% line
coverage.

Signed-off-by: Thomas Vincent <thomasvincent@gmail.com>

* style: apply php-cs-fixer to ss_entity_sensor.php

Signed-off-by: Thomas Vincent <thomasvincent@gmail.com>

---------

Signed-off-by: Thomas Vincent <thomasvincent@gmail.com>
2026-09-01 21:00:18 -07:00

127 lines
4.9 KiB
PHP

<?php
/*
+-------------------------------------------------------------------------+
| Copyright (C) 2004-2026 The Cacti Group |
+-------------------------------------------------------------------------+
| Cacti: The Complete RRDtool-based Graphing Solution |
+-------------------------------------------------------------------------+
*/
/*
* Unit tests for the ENTITY-SENSOR-MIB collector (issue #7355).
* Runs under the no-DB bootstrap. The collector's SNMP I/O is injected through
* its $walker seam, so every branch is exercised without a live device.
*/
// The script guards its CLI/script-server dispatch behind $called_by_script_server;
// set it so requiring the file only defines the functions.
$called_by_script_server = true;
if (!defined('SNMP_POLLER')) {
define('SNMP_POLLER', 'SNMP');
}
if (!function_exists('cacti_count')) {
function cacti_count(mixed $a): int { return is_array($a) ? count($a) : 0; }
}
require_once dirname(__DIR__, 4) . '/scripts/ss_entity_sensor.php';
/** A fake walker backed by an OID-keyed fixture. */
function _es_walker(array $fixture): callable {
return static function (string $oid) use ($fixture): array {
return $fixture[$oid] ?? [];
};
}
$OIDS = ss_entity_sensor_oids();
$FIXTURE = [
$OIDS['type'] => ['1' => '8', '2' => '10'], // celsius, rpm
$OIDS['value'] => ['1' => '235', '2' => '4200'],
$OIDS['scale'] => ['1' => '9', '2' => '9'], // units
$OIDS['precision'] => ['1' => '1', '2' => '0'],
$OIDS['status'] => ['1' => '1', '2' => '1'],
$OIDS['descr'] => ['1' => 'Inlet Temp', '2' => 'Fan 1'],
$OIDS['name'] => ['1' => 'Temp/1', '2' => 'Fan/1'],
];
test('scale: units precision one divides by ten', function () {
expect(ss_entity_sensor_scale(235, 9, 1))->toBe(23.5);
});
test('scale: milli magnitude applies a thousandths multiplier', function () {
expect(ss_entity_sensor_scale(5000, 8, 0))->toBe(5.0); // 5000 * 1000^-1 = milli
});
test('scale: out-of-range scale is treated as units and precision zero is a no-op', function () {
expect(ss_entity_sensor_scale(42, 99, 0))->toBe(42);
expect(ss_entity_sensor_scale(42, 9, 0))->toBe(42);
});
test('index prints one line per sensor', function () use ($FIXTURE) {
ob_start();
ss_entity_sensor('h', 1, '', 'index', '', '', _es_walker($FIXTURE));
expect(trim(ob_get_clean()))->toBe("1\n2");
});
test('num_indexes counts the sensors', function () use ($FIXTURE) {
expect(ss_entity_sensor('h', 1, '', 'num_indexes', '', '', _es_walker($FIXTURE)))->toBe(2);
});
test('query value returns scaled index!value pairs', function () use ($FIXTURE) {
ob_start();
ss_entity_sensor('h', 1, '', 'query', 'value', '', _es_walker($FIXTURE));
expect(trim(ob_get_clean()))->toBe("1!23.5\n2!4200");
});
test('query description returns the ENTITY-MIB label', function () use ($FIXTURE) {
ob_start();
ss_entity_sensor('h', 1, '', 'query', 'descr', '', _es_walker($FIXTURE));
expect(trim(ob_get_clean()))->toBe("1!Inlet Temp\n2!Fan 1");
});
test('query index maps each sensor index to itself', function () use ($FIXTURE) {
ob_start();
ss_entity_sensor('h', 1, '', 'query', 'index', '', _es_walker($FIXTURE));
expect(trim(ob_get_clean()))->toBe("1!1\n2!2");
});
test('query of an unknown field yields nothing', function () use ($FIXTURE) {
ob_start();
ss_entity_sensor('h', 1, '', 'query', 'bogus', '', _es_walker($FIXTURE));
expect(ob_get_clean())->toBe('');
});
test('get returns one scaled value for one index', function () use ($FIXTURE) {
expect(ss_entity_sensor('h', 1, '', 'get', 'value', '1', _es_walker($FIXTURE)))->toBe('23.5');
});
test('get for a missing index returns U', function () use ($FIXTURE) {
expect(ss_entity_sensor('h', 1, '', 'get', 'value', '9', _es_walker($FIXTURE)))->toBe('U');
});
test('get with a non-numeric raw value scales from zero', function () use ($OIDS) {
$fx = [$OIDS['value'] => ['1' => 'n/a'], $OIDS['scale'] => ['1' => '9'], $OIDS['precision'] => ['1' => '0']];
expect(ss_entity_sensor('h', 1, '', 'get', 'value', '1', _es_walker($fx)))->toBe('0');
});
test('an unknown command returns empty', function () use ($FIXTURE) {
expect(ss_entity_sensor('h', 1, '', 'reboot', '', '', _es_walker($FIXTURE)))->toBe('');
});
test('flatten keys rows by the trailing OID component and drops empties', function () {
$rows = [
['oid' => '.1.3.6.1.2.1.99.1.1.1.4.7', 'value' => ' 100 '],
['oid' => '', 'value' => 'x'],
];
expect(ss_entity_sensor_flatten('.1.3.6.1.2.1.99.1.1.1.4', $rows))->toBe(['7' => '100']);
});
test('with no injected walker the default SNMP walker is constructed', function () {
// An unknown command builds the default walker but never calls it, so this
// exercises the walker === null branch without live network I/O.
expect(ss_entity_sensor('127.0.0.1', 1, '2:161:500:0:10:public', 'noop'))->toBe('');
});
test('the SNMP walker factory returns a callable', function () {
expect(ss_entity_sensor_snmp_walker('127.0.0.1', ['2', '161']))->toBeCallable();
});