When a tenant Kubernetes cluster hits the 12m node-Ready deadline with fewer than two nodes joined, the failure path dumped only `describe nodes` and `get hr`. That cannot tell apart the two node-join failure sub-modes: a worker VM that never booted (virt-launcher Pending or OOMKilled) versus a VM that booted fine but whose kubelet never registered a Node. The tenant cilium-operator HelmRelease reports "InProgress" identically in both, so the current dump is not enough to diagnose the failure or design a fix. Dump scoped, guarded diagnostics before failing fast: - worker VM/VMI/virt-launcher state on the management cluster, which is what actually splits the two sub-modes; - tenant kubelet CSRs plus the talos-csr-signer sidecar log, which reveal a boot-but-no-Node stall. In-guest Talos/kubelet capture is deliberately left out: talosctl needs a tenant-cluster talosconfig the runner does not have (the tenant workers use a separate Talos CA from the management sandbox), so the gap is documented in the failure path rather than shipped as a call that would fail mTLS and capture nothing. Every capture is guarded with `|| true` so a capture failure never masks the real exit. Assisted-By: Claude <noreply@anthropic.com> Signed-off-by: Aleksei Sviridkin <f@lex.la>