Aleksei Sviridkin c983b5c404 fix(linstor): use severity warning instead of warn in piraeus-datastore alerts (#3799)
## What this PR does

Seven of the piraeus-datastore alert rules label themselves `severity:
warn`. Alerta, which the monitoring package ships as the alert sink,
validates that value and `warn` is not on its list. Every webhook
delivery for these alerts dies with a 500.

```
Severity (warn) is not one of security, critical, major, minor, warning,
indeterminate, informational, normal, ok, cleared, debug, trace, unknown
```

Alertmanager retries seven times and drops the notification, and the
alert never shows up anywhere. The affected rules are the LINSTOR/DRBD
ones, such as storage pool at capacity, lost quorum, unintentional
diskless and stuck resync. These are exactly the alerts you least want
silently dropped.

Found this on a v1.4.6 cluster where `linstorStoragePoolAtCapacity` was
genuinely firing. The cluster had 153 dropped notifications in 40
minutes and nothing in Alerta. Renaming the label to `warning`, which
the other three rules in the same file already use, stopped the failures
immediately and the alerts came through.

The same labels sit on `main` and in `v1.6.1`, so a backport to
`release-1.6` would be appreciated.

The test commit adds a bats guard so the next one gets caught in CI. It
walks every `PrometheusRule` and `VMRule` under `packages/` outside
vendored `charts/`, helm templates included, and fails on a severity
outside Alerta's default alarm model, which is exactly where `warn`,
`info`, `error` and `fatal` fall. Helm actions are stripped before the
file is read, so a rule behind a `{{- if }}` or an unquoted `{{
.Release.Namespace }}` is checked rather than skipped, and a file that
still does not parse fails the contract instead of thinning it out. On
the current tree that is 194 alerting rules in 41 scanned files.

The guard found one more on `main`. `DatabaseAutoscalerAtMax` in
`packages/system/keda/templates/alerts.yaml` carries `severity: info`,
which Alerta refuses the same way. It is renamed to `informational`, the
value the model has for that level and the one seven other rules in the
tree already use.

Moving that alert off `info` also stops `InfoInhibitor` in
`packages/system/monitoring-agents/alerts/general.rules.yaml` from
firing. That rule matches any `severity="info"` alert and carries
`severity: major`, so on `main` it usually reached Alerta whenever
`DatabaseAutoscalerAtMax` fired, even though the keda alert itself was
refused. After this change no rule carries `info`, so operators no
longer see that `InfoInhibitor` notification.

Fixes #2411.

### Screenshots

Not a UI change.

### Downstream repositories

Walked the trigger map against the diff. It touches severity labels
inside `packages/system/piraeus-operator/alerts/` and
`packages/system/keda/templates/`, plus a bats file under `hack/`. No
package is added or renamed, and there is no values schema, CRD, tooling
the satellites gate on or node contract change. Nothing downstream
restates these labels.

- [x] No downstream repository is affected by this change
- [ ] [cozystack/website](https://github.com/cozystack/website) -
follow-up:
- [ ]
[cozystack/terraform-provider-cozystack](https://github.com/cozystack/terraform-provider-cozystack)
- follow-up:
- [ ]
[cozystack/ansible-cozystack](https://github.com/cozystack/ansible-cozystack)
- follow-up:
- [ ] [cozystack/ccp](https://github.com/cozystack/ccp) - follow-up:
- [ ] [cozystack/talm](https://github.com/cozystack/talm) - follow-up:
- [ ] [cozystack/cozyhr](https://github.com/cozystack/cozyhr) -
follow-up:
- [ ] [cozystack/cozy-proxy](https://github.com/cozystack/cozy-proxy) -
follow-up:
- [ ]
[cozystack/cozystack-telemetry-server](https://github.com/cozystack/cozystack-telemetry-server)
- follow-up:
- [ ]
[cozystack/external-apps-example](https://github.com/cozystack/external-apps-example)
- follow-up:
- [ ] [cozystack/examples](https://github.com/cozystack/examples) -
follow-up:

### Release note

```release-note
fix(linstor): LINSTOR/DRBD alerts carried severity `warn`, which Alerta rejects, so they were never delivered. They now use the standard `warning` severity, and the keda at-max autoscaler alert moves from `info` to `informational` for the same reason.
```
2026-09-30 21:44:57 +03:00
..