The bin shim now loads .env from CWD (or any parent) without overwriting existing env vars, then reads COGNITUM_SEED_TOKEN. When present: - Default endpoint switches from http://169.254.42.1 (link-local, no auth) to https://169.254.42.1:8443 (LAN/HTTPS, bearer) - The token is passed as the pairing/bearer token on `register` - All subsequent SDK calls use the bearer-authenticated session Verified end-to-end against a live Seed: bearer-authed register, status, mesh, witness, query all work over HTTPS:8443. Self-signed dev cert is tolerated via NODE_TLS_REJECT_UNAUTHORIZED=0 in the smoke harness; plugin/SDK tolerance via tlsInsecure config (default true). Smoke results with bearer: 22/25 pass. The 3 remaining failures are real Seed-side state (rate-limited pair window from prior runs, SDK trust-score circuit breaker after repeated unauthorized attempts in the same in-process run, and store/ingest correctly classified as needing a write-scoped token vs. our read-scoped one). Plugin source (src/bin.ts): - New loadDotenv() walks up from CWD looking for .env, parses KEY=VALUE lines (handles quoted values, comments, blanks), sets process.env without overwriting. - SEED_DEFAULT_ENDPOINT = COGNITUM_SEED_ENDPOINT ?? (token ? lan : link-local) - register handler auto-injects --token from env if not explicitly passed - --help banner shows token status and endpoint mode Smoke harness: - Loads same .env, picks endpoint+token automatically - pair-window opener now checks status first (avoids HTTP 429 on already-open), passes bearer when available - ingest failure now classified as expected-on-read-scope-tokens Plugin README documents .env setup, COGNITUM_SEED_TOKEN, optional COGNITUM_SEED_ENDPOINT/IOT_FLEET_ID/IOT_ZONE_ID/IOT_TLS_INSECURE overrides, and the read-vs-write token scope distinction. Bump to 1.0.0-alpha.5; published to npm (alpha + latest). Co-authored-by: Reuven <cohen@ruv-mac-mini.local>
@claude-flow/plugin-iot-cognitum
IoT Cognitum Seed device-agent bridge — treat every Seed as a Ruflo agent with hardware capabilities.
Hardware
This plugin requires a Cognitum Seed device. Get one at https://cognitum.one.
The Seed is an edge appliance with on-device vector store, Ed25519 cryptographic identity, OTA firmware updates, mesh networking, and a witness chain for provenance.
Default endpoints:
http://169.254.42.1— link-local USB-C (no auth, read-only + pair window)https://169.254.42.1:8443— LAN/HTTPS with bearer token (full access including writes)
Install + run
npx -y -p @claude-flow/plugin-iot-cognitum@latest cognitum-iot --help
Authentication via .env
Create a .env file in your project root (or any parent directory):
COGNITUM_SEED_TOKEN=your-bearer-token-here
# Optional overrides:
COGNITUM_SEED_ENDPOINT=https://169.254.42.1:8443 # default when token is set
IOT_FLEET_ID=my-fleet
IOT_ZONE_ID=zone-1
IOT_TLS_INSECURE=true # accept self-signed cert (default: true)
The bin walks up from CWD looking for .env, loads it without overwriting existing process.env vars, then:
- When
COGNITUM_SEED_TOKENis present → default endpoint switches tohttps://169.254.42.1:8443(LAN/HTTPS) and the token is passed as the bearer/pairing token onregister. - When no token → default endpoint stays at
http://169.254.42.1(USB-C link-local, read-only).
Token scope on Seed varies — read endpoints work with most tokens; store/ingest and some admin operations require a write-scoped token. See https://cognitum.one for token tier documentation.
Commands
| Command | Description |
|---|---|
cognitum-iot init |
Show plugin configuration |
cognitum-iot register [endpoint] |
Register a Seed device (defaults to http://169.254.42.1) |
cognitum-iot list |
List registered devices |
cognitum-iot status <device-id> |
Show device trust score, vectors, epoch |
cognitum-iot mesh <device-id> |
Show mesh network topology |
cognitum-iot witness <device-id> |
Show witness chain |
cognitum-iot witness verify <device-id> |
Verify witness chain integrity |
cognitum-iot query --device-id <id> --vector "[..]" |
k-NN search the on-device vector store |
cognitum-iot ingest --device-id <id> --vector "[..]" |
Ingest a vector (requires bearer auth) |
cognitum-iot pair --device-id <id> |
Pair (requires open pair window on device) |
cognitum-iot unpair --device-id <id> |
Unpair (requires bearer auth) |
cognitum-iot fleet create --fleet-id <id> --name <name> |
Create a fleet |
cognitum-iot fleet list |
List fleets |
cognitum-iot fleet add --fleet-id <fid> --device-id <did> |
Add device to fleet |
cognitum-iot fleet remove --fleet-id <fid> --device-id <did> |
Remove device from fleet |
cognitum-iot fleet delete --fleet-id <id> |
Delete a fleet |
cognitum-iot firmware list |
List firmware rollouts |
cognitum-iot firmware status <rollout-id> |
Rollout status |
cognitum-iot firmware deploy <fleet-id> --version <ver> |
Start an OTA rollout |
cognitum-iot firmware advance <rollout-id> |
Advance rollout stage |
cognitum-iot firmware rollback <rollout-id> |
Force rollback |
Programmatic use
import { IoTCognitumPlugin } from '@claude-flow/plugin-iot-cognitum';
const plugin = new IoTCognitumPlugin();
await plugin.initialize({ /* PluginContext */ });
const coordinator = plugin['coordinator'];
const device = await coordinator.registerDevice('http://169.254.42.1');
console.log(`Trust: ${device.trustLevel}, vectors: ${device.vectorStoreStats.totalVectors}`);
Tests
239 unit + integration tests, plus a chained-command live-device smoke harness at __tests__/integration/full-plugin-smoke.mjs. Run:
npm test # unit + SDK integration
SEED_ENDPOINT=http://169.254.42.1 \
node __tests__/integration/full-plugin-smoke.mjs # live device smoke
License
MIT — Claude Flow Team.
Cognitum Seed hardware: see https://cognitum.one for licensing and acquisition.