# Automation Graph Rules
This section will describe **Graph Rules** in Cacti.
Graph rules are used by the Cacti automation process after a device has been
identified and a template has been applied the next step is graph creation.
Graph rules are processed from top to bottom.
These rules select indexed data-query graphs. Associated non-indexed graph
templates have a separate automatic creation path controlled by **Enable
Automatic Graph Creation**; they do not require a graph rule.
Device identification and graph selection are separate steps. A vendor or
[device template](Device-Templates.md) match does not prove that the device
exposes every measurement in that template. Confirm SNMP access and the
returned data-query rows before enabling a rule across a fleet. For queries
with optional tables or components, select only the rows and graph types
supported by the target devices.
The graph rule matches the graph template by looking at the data fields
chosen that are available in the data query for example below we are creating
graphs for interface traffic the data query has several fields available to
match on.
You can see how these rules would take place by clicking the show matching
objects link.
Use both **Show matching devices** and **Show matching objects** to review
the scope. These previews show rule matches, not proof that each selected
metric will poll successfully. Check the resulting graphs on representative
devices as well.
![Automation Graph Rules](images/automation-graph-rules.png)
A practical example if you want to create graphs for interfaces that are in
up/up status you would choose the ifOperstatus field and match the status to
UP this would tell automation to create the graph for that interface only if
the data query discovers the operational status is equal to up.
A device selection Criteria is also important Cacti needs a way to find which
device it needs to match. In the below example we are matching any device
that has an interface that is up and is not a Windows server.
You can preview which devices this will apply to by clicking the Show matching
devices link.
![Automation Graph Rules Edit](images/automation-graph-rules-edit1.png)
![Automation Graph Rules Device Criteria](images/automation-graph-rules-edit2.png)
![Automation Graph Rules Graph Criteria](images/automation-graph-rules-edit3.png)
This output shows us which devices match our devices rules this can help with
tweaking rules as needed.
![Automation Graph Rules Matching Devices](images/automation-graph-rules-edit4.png)
This output shows which interfaces,drives,sensors etc will be graphed based
on the graph rules.
![Automation Graph Rules Matching Objects](images/automation-graph-rules-edit5.png)
---
Copyright (c) 2004-2026 The Cacti Group